List Operation Commands
Copyright © Itech Electronic Co., Ltd. 44
Parameter 2
Time value, Float, unit: ms
Example
LIST:STEP:SD:SIT 3,20
Query syntax
LIST:STEP:SD:SITe?
Parameters
Number of steps, 0 ~ 99
LIST:STEP:SD:TIMe
This command is used to set the surge / notch duration of the LIST single-step.
Parameters 1 and 2 are mandatory.
Command syntax
LIST:STEP:SD:TIMe
Parameter 1
Number of steps, 0 ~ 99
Parameter 2
Time value, Float, unit: ms
Example
LIST:STEP:SD:TIM 3,20
Query syntax
LIST:STEP:SD:TIMe?
Parameters
Number of steps, 0 ~ 99
LIST:SAVe:BANK
This command is used to store the list file in the specified storage area.
Command syntax
LIST:SAVe:BANK <NR1>
Parameters
0~9