Maximum Power Point Scanning Commands
Copyright © Itech Electronic Co., Ltd. 46
Chapter11 Maximum Power Point Scanning
Commands
SWEep:STATe
This command is used to set the scan function status.
Command syntax
SWEep:STATe
Parameters
DISable|ENABle
Example
SWEep:STATe ENAB
Query syntax
SWEep:STATe?
SWEep:RECall
This command is used to invoke the scan file.
Command syntax
SWEep:RECall <NR1>
Parameters
0~9
Example
SWEep:REC 4
SWEep:STARt:VOLTage
This command is used to set the start voltage of the scan function.
Command syntax
SWEep:STARt:VOLTage <NR1>
Parameters
MINimum|MAXimum|Float