Function and Features
Copyright © Itech Electronics Co., Ltd. 23
Notes:
IT7321 has no GPIB and-Setup menu items.
3.9.2 Menu function
System menu
Initialize the system menu
relative factory default setup as follows:
Power-On
Sav0
Power-Out
Off
Buzzer
On
Trigger
Manual
Communication
RS232
Power-On
This parameter determines the state of the AC source after power up.If you
select “Rst”,the default output parameter settings will be active after power
up.The default setup is 0V,50HZ, 0° and 0°.If you select “Sav0”,then the AC
source will automatically recall the output parameters setting saved in 0 register
Note,please save these parameters in memory0 according to 3.7.
Power-Out
This parameter sets the output on/off state at power up.If you select “Last”,the
AC source will save the output state prior to power down and revert to that state
at power up.If you select “off”,the output state is always “off when the power
supply is turned on.The recommend setting is “OFF”.
Buzzer
This item can set the key sound state.If in ON mode,then when you press a
button, the power supply will beep. If in OFF mode,the beeper will not make a
sound.The default set is in ON mode.
Trigger source
This item can set the trigger signal to Keyboard trigger, Command trigger or
External trigger during surge/trapped wave test under List operation. If Manual
is selected, the trigger signal is provided by (Shift) + (Trigger) on
the panel; if Bus is selected, command trigger mode is used; if External trigger
is selected, the trigger signal is provided by the trigger terminal (BNC) at the
rear panel. BNC is a composite terminal. You need to set its function to I-Trigger
in the Menu. For details, refer to Section 3.13 BNC. Set Factory Setting to
Manual.
Setting of Communication Interface
This item can set communication modes of the power supply. IT7321/IT7322
Series has the following standard communication interfaces: LAN/USB /RS232;
and IT7322H/IT7324/IT7324H/IT7326/IT7326H Series has the following
standard communication interfaces: LAN/USB/RS232/GPIB. You can choose
any one of them to communicate.