System Commands
Copyright© Itech Electronic Co., Ltd. 55
Command syntax
[SOURce:]RANGe? <A/B/C/ALL>
Arguments
<A/B/C/ALL>
Returns
<AUTO|HIGH>
[SOURce:]PROTection:CLEar
This command is used to clear the latch. This latch disables input in case of
protection, e.g., OV or OC protection. All error conditions must be removed
before the latch is cleared. Input and then system recovers to the status before
any error happens.
Command syntax
[SOURce:]PROTection:CLEar < A/B/C/ALL >,< OT|OV|OC|OP|ALL >
Arguments
<A/B/C/ALL>,
< OT|OV|OC|OP|ALL>
Example
PROTection:CLEar A,ALL
Returns
None
[SOURce:]PROTection?
This command is used to query the mark for obtaining protection status.
Command syntax
[SOURce:]PROTection? < A>
Arguments
< A>
Returns
<value> Current protection value of device
[SOURce:]LOOPspeed
This command is used to set the loop speed of a phase.