System Commands
Copyright© Itech Electronic Co., Ltd. 83
Chapter12 Common Commands
*CLS
This command clears the following registers:
Standard event register
Query event register
Status byte register
Command syntax
*CLS
Arguments
None
*ESE
This command can set the parameter of standard event enable register.
Setting parameter can determine which bit of standard event register is 1
and the byte will enable ESB of status byte register is 1.
Register description:
Standard Event Status Register
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
PON
NU2
CME
EXE
DDE
QYE
NU1
OPC
OPC:Operation Complete
NU1Retain 1
QYE: Queryerror
DDEDevice-dependent error
EXEExecution error
CMECommand error
PONPower-on has occurred
Command syntax
*ESE <value>
Arguments
0255
Default set
Refer to *PSC command