System Commands
Copyright© Itech Electronic Co., Ltd. 71
Chapter10 Protection commands
PROTect:RMS:CURRent
This command is used to set the RMS protection current.
Command syntax
PROTect:RMS:CURRent <PARAllel|THREephase>,<float>
Arguments
Parameter 1<PARAllel|THREephase>:Device working mode
PARAllel,HREephase
Parameter 2<float>:Current rms
Query syntax
PROTect:RMS:CURRent? <PARAllel|THREephase>
Returns
<float>
PROTect:RMS:CURRent?
This command is used to query the RMS protection current.
Command syntax
PROTect:RMS:CURRent? <PARAllel|THREephase>
Arguments
Parameter 1<PARAllel|THREephase>:Device working mode
PARAllel,THREephase
Returns
<float>
PROTect:RMS:TIME
This command is used to set the delay time of RMS protection current.
Command syntax
PROTect:RMS:TIME <PARAllel|THREephase>,<float>
Arguments
Parameter 1:Device working mode