7. Set the voltage and frequency parameters in the sweep interface.
Parameters in the sweep interface are described as follows:
Parameter
Explain
Const mode
Sweep mode
CC and CR
End
Set the running state after the sweep
execution is finished:
off: Directly off the input after the
execution is finished;
Last: Keep the last waveform unchanged
after the execution is finished.
Normal: return to normal mode after the
sweep execution is finished.
Start Level
Set the starting value.
Stop Level
Set the ending value.
Step Level
Set the step value.
Mode
Set the sweep mode.
Time: Time Sweep Mode
Trig: Trigger mode
Time-back-forth: Step switching according
to time and scanning back and forth.
Trigger-back-forth: Step switching
according to trigger and scanning back and
forth.
Step time
Set the step time.
Repeat count
Repeat count
Waveform
Select sweep waveform
Sine
Square
Sawtooth
Triangle
Trapezoid