Copyright © Itech Electronic Co., Ltd. 25
1: indicates 11-20 groups, and so on.
DISPLAY
DISP-TIMER
Timer function
ON
Enable timer function
OFF(default)
Disable timer function
RS-232
RS-232
4800_8N 1
Baud rate 4800, data bit 8, none parity, stop bit 1
9600_8N 1
Baud rate 9600, data bit 8, none parity, stop bit 1
19200_8N 1
Baud rate 19200, data bit 8, none parity, stop bit 1
38400_8N 1
Baud rate 38400, data bit 8, none parity, stop bit 1
PROTOCOL
SCPI
Select SCPI protocol
FRAME
Select FRAME protocol
ADDRESS
ADDRESS= 0
Set the instrument’s address(0~31)
RUNMODE
RUN
Running mode at power on
NORMAL
Normal mode
BATTERY
Default in battery test mode at power on
PROG_TEST
Default in automatic test mode at power on
OCP_TEST
Default in OCP test mode at power on
OPP_TEST
Default in OPP test mode at power on
TESTMOD
TESTMODE
Automatic test editing mode
NEW
IT8500+ specialized automatic test editing mode
IT8500
Compatible with IT8500 Automatic Test Edit Mode
DEFAULT
DEFAULT
Factory default setting
NO
Do not return instrument to factory default settings.
YES
Return instrument to factory default settings.
> DEFAULT
This option is used to restore all settings in the system menu to factory setting
values. Select “YES” and press [Enter] to restore to factory setting values.
Otherwise, the original system menu settings will remain unchanged.
The factory system menu is as follows:
Power-on
Rst
Buzzer
On
Knob
Update(default)
Trigger
Mannual
Memory
Group=0
Displ
Off (default)
>Power-on
When the power-on parameter is selected as RST, the input state when the
load is powered on is the factory state. If SAV0 is selected, the input state at
power-on of the load is the value of SAVE 0.
>Trigger
When using the transient and list function, you need to use the electronic load

Table of Contents

Other manuals for ITech IT8500plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8500plus Series and is the answer not in the manual?

ITech IT8500plus Series Specifications

General IconGeneral
BrandITech
ModelIT8500plus Series
CategoryTest Equipment
LanguageEnglish

Related product manuals