Functions and Characteristics
Copyright © Itech Electronic Co., Ltd. 29
Operation steps
1. Press [Shift]+[3] keys, the interface displayed as follows:
LIST OFF CALL EDI
2. Operate key and move to EDI. Press [Enter] key.
3. Set the CC range.
LIST RANGE=3A
4. Edit number of steps. Press [2] key to edit two steps. Press [Enter] key.
LIST STEP=2(2-84)
5. Edit current value in step 1 and press [Enter] key.
STEP 01 =1A
6. Edit slope in step 1 and press [Enter] key.
STEP 01 =0.1A/US
7. Edit time in step 1 and press [Enter] key.
STEP 01 =5S
8. Edit current value in step 2 and press [Enter] key.
STEP 02 =2A
9. Edit slope in step 2 and press [Enter] key.
STEP 02 =0.1A/US
10. Edit time in step 2 and press [Enter] key.
STEP 02 =5S
11. Edit repeat count and press [Enter] key.
REAPEAT =3
12. Save the edited file and press [Enter] key.
SAVE LIST =1(1-7)
13. Operate key and move to OFF. Press [Enter] key (In this case,
OFF changes to ON, and the VF status indicator Trig lamp of the VFD
display is illuminated). Press [ESC] key to exit setting.
LIST OFF CALL EDI
14. Press [On/Off] key to open input and press [Shift] + key (Trigger key).
15. Press [CC]/ [CV]/ [CR]/ [CW] key or any composite function key to exit List
test function.
For direct recall of existing List files and triggering of List operation, refer to
steps below:
Operation steps
1. Press [Shift] +3 keys.
LIST OFF CALL EDI
Ensure that OFF lamp flicks. If not, press [Enter] to change the lamp from
ON to OFF.
2. Press key to select CALL. And press [Enter] for confirmation.
3. Select edited file and press [Enter] for confirmation.
RECALL LIST = 1