Status Commands
Copyright © Itech Electronic Co., Ltd. 49
Chapter5 Status Commands
STATus:QUEStionable?
This command is used to read the value of Questionable Event register.
Electronic load will return a decimal number which is the binary weighted sum
of each bits of register. All these bits value is latched and will be cleared after
executing this command.
Query Syntax:
STATus:QUEStionable[:EVENt]?
Parameter:
None
Returned value:
<NR1>
Relevant Command:
STATus:QUEStionable:ENABle
STATus:QUEStionable:CONDition?
This command is used to read the value of query condition register to get the
AC load’s status, such as ocpeak/ocrms/ov/op/ot.
Query Syntax:
STATus:QUEStionable:CONDition?
Parameter:
None
Returned value:
<NR1>
STATus:QUEStionable:ENABle
This command sets or reads the value of the Questionable Enable register and
the AC load will return back a decimal value which is a binary weighted sum of
all bits from the enable register.