Electric installation
AirModule 6 720 813 268(2014/10)
30
8.9 Power supply heat pump and heat pump module 15 kW
Fig. 30 Power supply heat pump and heat pump module 15 kW
[1] Input 400 V 3 N~
[2] User interface
[3] Heat pump
[4] Immersion heater/pressure switch alarm output ([2] Fig. 31)
[5] Installer module operating voltage ([1] Fig. 31)
[F1] Terminal fuse
[F2] Heat pump fuse
[EE] Immersion heater
[FE] Immersion heater overheating protection
[P] Pressure switch
[K1] Contactor step 1
[K2] Contactor step 2
[K3] Contactor step 3
• Immersion heater: 3-6-9-12-15 kW
1
2
3
4
5
6 720 809 156-38.2I
Delivered connected
Connected during installation/
accessories