EasyManua.ls Logo

Jacobsen GA 24 - Shift Control Cable; Lift Cable

Jacobsen GA 24
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADJUSTMENTS 6
17
6.6 SHIFT CONTROL CABLE ___________________________________________________
If traction drive system does not shift properly,
adjustment of the shift control cable may be required.
1. Disconnect clevis (N) from shift lever (P).
2. Place the shift control lever in the L position.
3. Rotate shift lever (P) clockwise until it locks into the
low speed detent.
4. Adjust cable nuts (M) as required until clevis (N)
aligns with mounting hole in lever (P).
5. If additional adjustment is required, cable may be
adjusted at the handle.
6. Test each position of shift control. Shift lever (P)
should lock into each detent at each stop of shift
control.
Figure 6F
6.7 LIFT CABLE ______________________________________________________________
If aerator head does not raise or lower properly,
adjustment of the lift cable may be required.
1. Loosen both cable nuts (R). Lift valve should
automaticaly return to center.
2. Place lift control handle in center (neutral) position.
3. Tighten nuts (R).
4. Test operation of lift control.
Figure 6G
M
N
P
R

Table of Contents