Starting the Engine
39 9831/7750-1 39
9. Turn the ignition key to the start position and hold it there until the engine starts. An extended period of
cranking will be required before the engine starts. An engine "warm up" period will follow and only then will
operating revs be available. Do not operate the starter motor for more than the time specified.
Duration: 30 s
10. If the engine does not start, turn the ignition key to the off position.
11. Let the starter motor cool for a few minutes before you repeat the steps 9 and 10
Duration: 3 min
12. When the engine has started, check the all warning lights (excluding the neutral and park brake warning
lights) have gone off.
13. Do not race the engine until the oil pressure low light has gone out.