10. How to use the bobbin counter
B
C
A
– 42 –
In the case the number of stitches that can be counted on the bobbin counter (Function setting number
P113) is set to "x10", the bobbin count complete screen is displayed when the bobbin counter reaches the
set value to notify the operator that the bobbin has to be changed.
1) Call function setting No. P113 referring to
"II-4.
Setting of functions" p.26
.
Conrm the data with
.
2) Press
to
to set the bobbin
counter value (
B
).
When the bobbin counter reaches the "bobbin
counter value x 10", the bobbin count complete
screen is displayed.
3) Press
to determine the set value and
return the sewing machine to the normal sewing
state.
4) Carry out sewing. When the bobbin counter value
becomes "0" (zero), the count complete screen is
displayed.(
C
)
When you press
, the current value on
the bobbin counter returns to the value set with
"function setting No. P113 Bobbin counter" and
the sewing machine returns to the normal sewing
state.