EasyManuals Logo

KEB COMBIVERT F6 Instruction Manual

KEB COMBIVERT F6
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
GB - 39
Annex
Storage period < 1 year
Start-up without special measures
Storage period 1…2 years
Operate frequency inverter one hour without modulation
Storage period 2…3 years
Remove all cables from the power circuit; especially of braking resistor or module
Open control release
Connect variable transformer to inverter input
Increase variable transformer slowly to indicated input voltage (>1 min) and remain at
leastonthespeciedtime.
Voltage class Input voltage Residence time
400 V
0…280 V 15 min
280…400 V 15 min
400…500 V 1 h
Storage period > 3 years
Input voltages as before, however double the times per year. Eventually change capac-
itors.
After expiration of this start-up the KEB COMBIVERT can be operated on nominal rating con-
ditions or delivered to a new storage.
A.5.1 Cooling circuit
The cooling circuit must be completely empty if a unit shall be switched off for a longer period.
The cooling circuit must be blown out additionally with compressed air at temperatures below
0°C.

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals