Calibration Messages
C-4
ohm2[20]gain
ohm2[20]offset
ohm2[200]gain
ohm2[200]offset
ohm2[2k]gain
ohm2[2k]offset
ohm2[20k]gain
ohm2[20k]offset
ohm2[200k]gain
ohm2[200k]offset
ohm2[2M]gain
ohm2[2M]offset
ohm2[20M]gain
ohm2[20M]offset
ohm2[200M]gain
ohm2[200M]offset
ohm2[1G]gain
ohm2[1G]offset
ohm4[20]gain
ohm4[20]offset
ohm4[200]gain
ohm4[200]offset
ohm4[2k]gain
ohm4[2k]offset
ohm4[20k]gain
ohm4[20k]offset
ohm4[200k]gain
ohm4[200k]offset
n7vref
rollover
mux4d711
mux4d711p5
mux4d215
mux4d011
mux4d015
mux4d0150
mux4d011p5
mux4dF150
mux4dF15
i20
i200
i2k
i20k
i200k
i2m
i20m
i200m
i1g
2-wire 20¾ gain
2-wire 20¾ offset
2-wire 200¾ gain
2-wire 200¾ offset
2-wire 2k¾ gain
2-wire 2k¾ offset
2-wire 20k¾ gain
2-wire 20k¾ offset
2-wire 200k¾ gain
2-wire 200k¾ offset
2-wire 2M¾ gain
2-wire 2M¾ offset
2-wire 20M¾ gain
2-wire 20M¾ offset
2-wire 200M¾ gain
2-wire 200M¾ offset
2-wire 1G¾ gain
2-wire 1G¾ offset
4-wire 20¾ gain
4-wire 20¾ offset
4-wire 200¾ gain
4-wire 200¾ offset
4-wire 2k¾ gain
4-wire 2k¾ offset
4-wire 20k¾ gain
4-wire 20k¾ offset
4-wire 200k¾ gain
4-wire 200k¾ offset
7V reference value
±2V rollover
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
Multiplexer 4-1/2 digit counts (AC peak)
20¾ range current source value
200¾ range current source value
2k¾ range current source value
20k¾ range current source value
200k¾ range current source value
2M¾ range current source value
20M¾ range current source value
200M¾ range current source value
1G¾ range current source value
NOTE: All values are expressed in NR3 format (floating point with exponent). Constants are listed in order transmitted and are separated by commas.
Table C-2 (continued)
Calibration constants returned by :CAL:PROT:DATA? Query
Constant Description

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals