EasyManuals Logo
Home>Keithley>Multimeter>2001

Keithley 2001 Calibration Manual

Keithley 2001
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Table of Contents
i
1 Performance Verification
1.1 Introduction.......................................................................................................................................................... 1-1
1.2 Environmental conditions .................................................................................................................................... 1-1
1.3 Warm-up period ...................................................................................................................................................1-1
1.4 Line power ...........................................................................................................................................................1-1
1.5 Recommended test equipment .............................................................................................................................1-2
1.6 Verification limits ................................................................................................................................................ 1-2
1.7 Restoring default conditions ................................................................................................................................1-2
1.8 Verification procedures........................................................................................................................................1-4
1.8.1 DC volts verification....................................................................................................................................1-4
1.8.2 AC volts verification....................................................................................................................................1-5
1.8.3 DC current verification .............................................................................................................................. 1-10
1.8.4 AC current verification .............................................................................................................................. 1-11
1.8.5 Resistance verification ............................................................................................................................... 1-13
1.8.6 Frequency accuracy verification ................................................................................................................1-16
1.8.7 Temperature reading checks ......................................................................................................................1-17
2Calibration
2.1 Introduction.......................................................................................................................................................... 2-1
2.2 Environmental conditions .................................................................................................................................... 2-1
2.3 Warm-up period ...................................................................................................................................................2-2
2.4 Line power ...........................................................................................................................................................2-2
2.5 Calibration lock....................................................................................................................................................2-2
2.5.1 Comprehensive calibration lock...................................................................................................................2-2
2.5.2 Low-level calibration lock ...........................................................................................................................2-2
2.5.3 IEEE-488 bus calibration lock status........................................................................................................... 2-2
2.6 IEEE-488 bus calibration commands and program ............................................................................................. 2-2
2.6.1 Calibration commands .................................................................................................................................2-2
2.6.2 Required order of command execution........................................................................................................2-4
2.6.3 Example calibration command program......................................................................................................2-4
2.7 Calibration errors .................................................................................................................................................2-5

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals