OPERATION
TP-6901 3/16a Operation 19
Fuel Specifications
NOTICE
Natural gas and propane installations must be
installed in accordance with applicable federal,
state, and local law, and with the National Fire
Protection Association (NFPA) Pamphlet #58,
standard for storage and handling of Liquefied
Petroleum Gases, to the extent that these
standards are not in violation of federal, state, or
local law.
Table 4-1: Fuel Specifications
Fuel Type Item
Specification
KG2204 KG2204T
Liquid Propane
Gas (LPG)
Type HD-5 or HD-10
Maximum fuel pressure
(engine OFF, no load)
11.0" W.C.
Minimum fuel pressure
(engine ON, full load)
5.0" W.C.
Natural Gas (NG) Supply Standard pipeline
Approximate supply volume 37.257 kJ/m
3
(1000 BTU/ft.
3
)
Minimum flow
11.9 m
3
/hr. (420 SCFH)
@ 5.0" W.C.
19.6 m
3
/hr. (690 SCFH)
@ 5.0" W.C.
Allowable water vapor
Less than 112.3 kg per 1 million m
3
(Less than 7 lb. per 1 million ft.
3
)
Maximum fuel pressure
(engine OFF, no load)
11.0" W.C.
Minimum fuel pressure
(engine ON, full load)
5.0" W.C.
LPG and NG
(both)
Fuel handling and supply
component constraints
UL 2200: Standard for Stationary Engine Equipment
Assemblies
Operating temperature range –20°C (–4°F) to 105°C (221°F)

Table of Contents

Other manuals for Kohler KG2204

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KG2204 and is the answer not in the manual?

Kohler KG2204 Specifications

General IconGeneral
BrandKohler
ModelKG2204
CategoryEngine
LanguageEnglish

Related product manuals