MAINTENANCE
TP-6901 3/16a Maintenance 39
5.7 FUEL SYSTEM
NOTE:
Fuel system components are not adjustable and
cannot be serviced. Contact your authorized KOHLER
authorized distributor/dealer for replacements.
Check Fuel Supply Pipe and
Connections
With the fuel valve fully opened and the engine
stopped, check all fuel system connections and lines
for leaks using a soapy water solution. Correct any
leaks before restarting the engine. Do not start the
engine if you can smell leaking gas. Have any
necessary service performed by a KOHLER authorized
distributor/dealer or qualified LPG/NG technician only.
Check Fuel Level (LPG only)
With the fuel valve on the LPG tank fully closed and the
engine stopped, check the fuel gauge on the LPG tank.
Make sure that the tank contains enough fuel for
sustained operation. If not, refill the tank before
restarting the engine.
Fully open the fuel valve on the LPG tank. Check all
fuel supply connections and lines for leaks using a
soapy water solution. Correct any leaks before
restarting the engine. Have any necessary service
performed by a KOHLER authorized distributor/dealer
or qualified LPG/NG technician only.
WARNING
!
Explosive fuel can cause fires and
severe burns.
If a gaseous odor is detected,
ventilate the area and contact an
authorized service technician.
LPG (Liquefied Petroleum Gas) is extremely
flammable and tends to settle in low areas where a
spark or flame could ignite the gas. Do not start or
operate this engine in a poorly ventilated area where
leaking gas could accumulate and endanger the safety
of persons in the area.
NG (Natural Gas) is extremely flammable, is lighter
than air, and rises. Do not start or operate this engine
in a poorly ventilated are where leaking gas could
accumulate and endanger the safety of persons in the
area.
To ensure personal safety, installation and repair of
LPG/NG fuel supply systems must be performed only
by qualified LPG/NG system technicians. Improperly
installed and maintained LPG/NG equipment could
cause the fuel supply system or other components to
malfunction, causing gas leaks.
Observe federal, state, and local laws governing
LPG/NG fuel, storage, and systems.

Table of Contents

Other manuals for Kohler KG2204

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KG2204 and is the answer not in the manual?

Kohler KG2204 Specifications

General IconGeneral
BrandKohler
ModelKG2204
CategoryEngine
LanguageEnglish

Related product manuals