MAINTENANCE
SERVICE PROCEDURE
CHECK WATER SEPARATOR, WASH INSIDE OF FILTER CASE
WARNING
Do not bring any fire or flame close.
NOTICE
When carrying out inspection and maintenance of the fuel system, the particularly careful not to let any dirt or dust get in. If
there is any dirt of dust around the fuel system, clean it off thoroughly with fuel before starting the operation.
To prevent dirt or dust from getting into the fuel circuit, remove all dirt and dust from the surrounding area before starting the
operation.
Prepare a container to catch the fuel.
1.
Open the inspection cover on the left side of the machine.
2. Put a container under the water separator to catch the drained
water.
3.
Loosen plug (1) and drain the fuel from inside the case.
4.
If the fuel cannot be drained, remove air intake plug (2). (Width
across flats: 14 mm (0.6in))
The fuel will drain from plug (1).