MAINTENANCE
SERVICE PROCEDURE
MAINTENANCE
SERVICE PROCEDURE
8. Close air bleeding valve (2).
9.
Start the engine. If the engine does not start, try again by following the steps below.
1)
Check that air bleeding valve (2) is closed.
2) Tilt electric priming pump switch (3) to the ON position.
3)
Try to start the engine while the electric priming pump is in operation. If the engine still does not start, wait
for approx. 2 minutes, and then repeat steps 2) and 3).
4) After the engine has started, run the engine for approx. 5 minutes to bleed air from the fuel system
completely.
NOTICE
Do not keep the starting motor rotating continuously for more than 20 seconds.
If the engine will not start, wait for at least 2 minutes before trying to start the engine again.
4 - 39