General view
(1) Torque converter lockup switch
(2) Torque converter lockup mode display
(3) Shift indicator (indicates actual gear speed)
The lockup is activated or canceled at the following speed.
Lockup
Gear speed
Forward travel speed
 km/h
Reverse travel speed
 km/h
Actuated Canceled
Actuated Canceled
2nd 8.0 to 11.0 7.0 to 8.0 9.0 to 12.0 8.0 to 9.0
3rd 14.0 to 18.0 14.0 to 15.0 15.0 to 19.0 14.0 to 16.0
4th 22.0 to 26.0 22.0 24.0 to 28.0 23.0
TRAVEL SPEED WARNING FUNCTION
Travel speed warning function
(This function works even when the torque converter lockup function mode is OFF.)
When the
travel speed reaches 40.0 km/h or above,
the centralized warning lamp lights up and the alarm buz-
zer sounds.
If the alarm buzzer sounds, depress the brake immediately to reduce the travel speed.
The alarm buzzer stops sounding when the travel speed is reduced to 39.5 km/h or below.
METHOD FOR OPERATING WORK EQUIPMENT
NOTICE
Even
if the
engine is stopped, if the starting switch is at ON position and lock of the work equipment is
canceled (pilot lamp is not lit), the work equipment can be operated.
Boom control lever (1) and bucket control lever (2) are used to
operate the boom and bucket in the following manners.
OPERATION MACHINE OPERATIONS AND CONTROLS
3-203