(A): Plug mounting hole (M16: O-ring boss)
(B): Releasing screw hole (M12)
METHOD FOR OPERATING MACHINE IN EMERGENCY
The normal
gear shifting operation is performed by electric signals. If there should be a failure in the electrical
system, and the machine does not move, ask your Komatsu distributor.
NOTICE
If an emergency travel operation is needed, ask your Komatsu distributor to perform it.
PRECAUTIONS FOR DISCHARGED BATTERY
kk
WARNING
• It is dangerous to charge a battery when installed on a
machine. Make
sure that it is removed before charg-
ing.
• When checking or handling the battery, stop the en-
gine and turn the starting switch and battery discon-
nect switch keys to OFF positions.
• The battery generates hydrogen gas, and it is danger-
ous that it may explode. Do not bring open flame such
as lighted cigarettes near the battery, or do nothing
that will cause sparks.
• Battery electrolyte is dilute sulfuric acid, and it will at-
tack your clothes and skin. If it gets on your clothes or
on your skin, immediately wash it off with a large
amount of clean water.
If it gets in your eyes, wash the eyes immediately with
clean water, then consult a doctor for medical treat-
ment.
• When handling batteries, always wear protective eye-
glasses and rubber gloves.
• When removing the battery, first disconnect the cable
from the ground (normally the negative (-) terminal).
When installing, first connect the cable to the positive
(+) terminal.
If a tool touches the positive terminal and the chassis,
it is dangerous that it may cause a spark. Be extremely
careful.
• If the terminals are loose, it is dangerous that the de-
fective contact may generate sparks, and it may cause
an explosion.
Install the cable terminals securely.
• When removing or installing the cable terminals,
check which is the positive (+) terminal and which is
the negative (-) terminal.
TROUBLES AND ACTIONS OPERATION
3-248

Table of Contents

Other manuals for Komatsu WA380-8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu WA380-8 and is the answer not in the manual?

Komatsu WA380-8 Specifications

General IconGeneral
BrandKomatsu
ModelWA380-8
CategoryCompact Loader
LanguageEnglish

Related product manuals