3 Transport/Storage/Disposal
14 of 92
KSB Delta Macro
1983.843/04-EN
6. Attach lifting equipment to the pressure booster system.
7. Separate the pressure booster system from the wooden skids with a suitable
tool. Lift the pressure booster system off. Dispose of the wooden skids.
8. Carefully place down the pressure booster system at the site of installation.
Example: Lifting the pressure booster system and control cabinet separately
If the control cabinet is too large and cannot be placed on the baseplate of the
pressure booster system, the pressure booster system and control cabinet have to be
lifted separately.
C
B
Fig.2: Lifting the pressure booster system and control cabinet separately
ü Before lifting the pressure booster system and control cabinet, disconnect the
power cables.
1. Attach lifting beams to the lifting lugs (B) provided at the baseplate.
2. Use an anti-tilting device (C).