53HYDRAULIC UNIT
BLoader / Remote Control Valve Lever
1. Before moving the lever, make sure that the hydraulic
hoses for attachments are connected.
2. Move the lever diagonally (a, b, c shown in the figure),
and the first and second segments can be controlled
simultaneously.
A Move the lever to the "FLOAT" position, and it will be
held there by the detent mechanism. To use the valve
as a floating valve with detents, connect the hydraulic
hoses to ports [A] and [B].
A When taking off hydraulic power from port [D], the flow
rate can be adjusted in 2 stages with the lever.
The flow rate is high at position (R1) and low at
position (R2). Move the lever to position (R1) or (R2)
depending on the attachment in use.
BValve Lock
To avoid injury or death from crushing:
A Do not utilize the valve lock for machine
maintenance or repair.
A The valve lock is to prevent accidental
actuation when implement is not in use or
during transport.
The control valve is equipped with a valve lock feature.
The control valve is locked in the "LOCK" position.
The lock is not intended and will not prevent a leak down
of the implement during the period of storage.
(1) Lock lever (A) "UNLOCK"
(B) "LOCK"

Table of Contents