26
3 Product Description
3.6.6 Technical Data external Housing Ex-Zone I
Fig. 3-25 External power unit Ex-Zone I
Fig. 3-26 Dimensions of the External power unit - Ex-Zone I
Technische Daten
Explosion protection: II 2 G Ex db IIB + H2 T6/T5 GbII 2 D Ex tb IIIC T80 °C...T95 °C Db
Material: copper-free aluminium, stainless steel 1.4404/316
Certificates/Test certificates: ITS 15 ATEX 18302X, IECEx ITS 15.0041X
Electrical safety: IP 66 according to EN 60529
Impact resistance: 7 Joule according to EN 60079-0
Temperatureinsatzbereich: -20 °C ... +60 °C (-4 ... 140 °F)