63
8 Decommissioning and Storage
8.1 Decommissioning
Take the pilot burner out of operation and remove
CAUTION!
Residual heat on all parts of the system and the pilot burner.
Risk of contact burns.
Allow the system and pilot burner to cool down before removal.
Procedure:
1 Shut down the system and secure it from being switched on again.
2 Allow the pilot burner to cool down completely.
3 Shut off the gas and air supply.
4 Depressurise the gas and air supply systems and disconnect them.
5 Disconnect the electrical connections and ensure that there is no voltage present.
6 Loosen the grub screws.
7 Pull the pilot burner out of the flange.
8.2 Storage
Procedure:
1 Perform a complete maintenance, see chapter 6.3 Perform Maintenance, to ensure that
the ignition burner is operationally ready for the next use.
2 Seal off the connections for gas and air supply to prevent contamination.
3 Store the ignition burner in the original packaging together with these
operating instructions under appropriate storage conditions, see chapter 3.6 Technical
Data.