Page 5
BLOWER PERFORMANCE DATA
G26Q2-50 BLOWER PERFORMANCE
External Static
Air Volume and Motor Watts at Specific Blower Taps
Pressure
High Medium Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts
0 0 1115 525 495 885 415 360 720 340 280
.10 25 1095 515 475 880 415 350 700 330 265
.20 50 1065 505 465 855 405 340 680 320 260
.30 75 1035 490 445 830 390 325 660 310 250
.40 100 995 470 425 755 355 315 645 305 235
.50 125 950 450 405 755 355 300 625 295 225
.60 150 900 425 390 740 350 280 540 255 215
.70 175 815 385 365 660 310 255 530 250 205
.80 200 610 290 340 585 275 240 360 170 180
.90 225 590 280 315 390 185 215 - - - - - - - - - - - -
NOTE All air data is measured external to unit with 1 in. (25 mm) cleanable foam filter (not furnished) in place. Also see Filter Air Resistance table.
G26Q3-50 BLOWER PERFORMANCE
External Static
Air Volume and Motor Watts at Specific Blower Taps
Pressure
High Medium-High Medium-Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0 0 1485 700 590 1275 600 485 1045 495 390 840 395 310
.10 25 1445 680 565 1250 590 460 1030 485 375 830 390 300
.20 50 1390 655 545 1225 580 445 1010 475 365 815 385 290
.30 75 1345 635 520 1190 560 425 985 465 345 790 375 285
.40 100 1290 610 500 1150 545 405 955 450 335 780 370 275
.50 125 1225 580 480 1095 515 385 920 435 315 735 345 255
.60 150 1160 545 460 1030 485 365 875 415 300 700 330 240
.70 175 1075 505 440 950 450 345 855 405 280 600 285 220
.80 200 975 460 415 865 410 315 645 305 250 510 240 195
.90 225 845 400 385 615 290 265 545 255 225 375 175 180
NOTE All air data is measured external to unit with 1 in. (25 mm) cleanable foam filter (not furnished) in place. Also see Filter Air Resistance table.
G26Q3-75 BLOWER PERFORMANCE
External Static
Air Volume and Motor Watts at Specific Blower Taps
Pressure
High Medium-High Medium-Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0 0 1490 705 650 1340 630 540 1060 500 440 870 410 360
.10 25 1435 675 625 1305 615 515 1050 495 425 865 410 350
.20 50 1385 655 605 1260 595 490 1025 485 405 850 400 335
.30 75 1330 630 580 1215 575 470 1000 470 385 835 395 325
.40 100 1260 595 560 1160 545 445 965 455 365 810 380 310
.50 125 1200 565 540 1100 520 420 920 435 345 770 365 290
.60 150 1125 530 515 1035 490 400 870 410 325 735 345 280
.70 175 1035 490 495 960 455 375 780 370 305 685 325 265
.80 200 935 440 475 865 410 345 725 340 285 - - - - - - - - - - - -
.90 225 805 380 445 630 295 295 540 255 240 - - - - - - - - - - - -
NOTE All air data is measured external to unit with 1 in. (25 mm) cleanable foam filter (not furnished) in place. Also see Filter Air Resistance table.
G26Q4/5-75 BLOWER PERFORMANCE
External Static
Air Volume and Motor Watts at Specific Blower Taps
Pressure
High Medium-High Medium Medium-Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0 0 2415 1140 1240 2120 1000 1015 1875 885 855 1635 770 705 1430 675 585
.10 25 2330 1100 1200 2090 985 1005 1835 865 835 1615 760 700 1420 670 585
.20 50 2265 1070 1165 2045 965 990 1795 845 815 1580 745 690 1390 655 580
.30 75 2210 1045 1145 2000 945 970 1765 835 810 1545 730 675 1365 645 575
.40 100 2145 1010 1110 1950 920 955 1720 810 795 1510 715 670 1340 630 570
.50 125 2075 980 1085 1885 890 930 1680 795 785 1475 695 665 1310 620 565
.60 150 2000 945 1060 1825 860 910 1630 770 770 1435 675 655 1270 600 555
.70 175 1935 915 1040 1775 840 895 1565 740 755 1395 660 645 1220 575 545
.80 200 1840 870 1005 1705 805 870 1515 715 745 1345 635 630 1165 550 535
.90 225 1760 830 980 1610 760 845 1455 685 725 1275 600 615 1110 525 530
NOTE All air data is measured external to unit with 1 in. (25 mm) cleanable foam filter (not furnished) in place. Also see Filter Air Resistance table.