System modules
MCTRL_MotorControl (node number 131)
Speed setpoint limitation
13
358
EDBCSXA064 EN 3.2
13.20.6 Speed setpoint limitation
A speed setpoint limitation can be set via C0909.
ƒ You define the speed setpoint via MCTRL_nNSet_a in [%] of n
max
.
ƒ N
max
is selected via C0011. ( 357)
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C0909 speed limit 1
Limitation of direction of
rotation for speed setpoint
358
1 −175 ... +175 %
2 0 ... +175 %
3 −175 ... 0 %