For speed control with a servo inverter, the servo motor can be equipped with the following
feedback systems:
Inverter Feedback without funconal safety
Resolver Absolute value encoder Digital absolute value encoder
for OCT
i950 servo inverter RS0 AM128-8V-H AM20-8V-D
i700 servo inverter RS0 AM128-8V-H -
8400 TopLine inverter drives RS0 AM128-8V-H -
9400 HighLine servo drives RS0 AM128-8V-H -
Inverter Feedback with funconal safety
Resolver Absolute value encoder Digital absolute value encoder
for OCT
i950 servo inverter RV03 AM128-8V-K2 AM20-8V-D2
9400 HighLine servo drives RV03 AM128-8V-K2 -
Feedbacks in the environment of funconal safety
Motors can perform speed-dependent safety funcons for safe speed and/or safe relave
posion monitoring in a drive system by Lenze inverters or Controllers. In case of inverters,
these funcons are implemented by integrable safety modules and in case of Controllers by
the addionally required Safety Controller.
When planning systems/installaons of this kind, always observe the following:
When using just one single feedback system in the environment of these safety
applicaons, the applicable safety engineering standard IEC 61800-5-2 (adjustable speed
electrical power drive systems - Part: 5-2: Safety requirements - Funconal) spulates
special requirements for the connecon between feedback system and motor sha.
This is due to the fact that two-channel safety systems at this point in the mechanical
system are actually designed as single-channel systems. If this mechanical connecon is
designed with considerable overdimensioning, the standard permits exclusion of the fault
"encoder-sha breakage" or "encoder-sha slip". As such, the permissible angular
acceleraon limit values must not be exceeded for the individual drive soluons.
You can nd the limit values in the corresponding feedback data of the individual motor
ranges.
Speed-dependent safety funcons
Examples of speed-dependent safety funcons:
Safe stop 1 (SS1)
Safe operaonal stop (SOS)
Safely limited speed (SLS)
Safe maximum speed (SMS)
Safe direcon (SDI)
Operaon mode selector (OMS) with conrmaon (ES)
Safe speed monitor (SSM)
Safely limited increment (SLI)
Product extensions
Feedback
138

Table of Contents

Other manuals for Lenze g500-B110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze g500-B110 and is the answer not in the manual?

Lenze g500-B110 Specifications

General IconGeneral
BrandLenze
Modelg500-B110
CategoryEngine
LanguageEnglish

Related product manuals