Standards and operang condions
Conformies and approvals
Conformies
CE
2011/65/EU RoHS Direcve
2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TP TR 004/2011 Eurasian conformity: Safety of low voltage equipment
TP TC 020/2011 Eurasian conformity: Electromagnec compability of technical means
Approvals
CEL CEL 038-2020 Energy eciency for China. Aected motors receive a separate label.
cULus
-
UL 1004-1
for USA and Canada (requirements of the CSA
22.2 No. 274)
UL 1004-6
UkrSepro for Ukraine
Protecon of persons and device protecon
Degree of protecon
EN
EN 60529,EN
60034-5
IP54
Informaon applies to the mounted and ready-
for-use state
IP65
Temperature class
Insulaon system EN 60034-1 F (155 °C) Insulaon system
Permissible voltage
Limit curve A of the
pulse voltage
IEC/TS
60034-25:2007
IEC/TS 60034-25:2007
IVIC C IEC 60034-18-41 at 500 V
EMC data
Noise emission
Fullls requirements
according to
EN 60034-1 A nal overall assessment of the drive system is indispensable
Noise immunity
Fullls requirements
according to
EN 60034-1 A nal overall assessment of the drive system is indispensable
Environmental condions
Climate
Storage
EN IEC
60721-3-1:1997
1K3 (-20 ... +40 °C) >3 months
1K3 (-20 ... +60 °C) <3 months
Transport
EN IEC
60721-3-2:1997
2K3 (-20 ... +70 °C)
Operaon
EN IEC
60721-3-3:1995 +
A2:1997
3K3 (-10 ... +40 °C) Operaon, without brake
3K3 (-15 ...+40 °C) Operaon without brake, forced venlated
3K3 (-20 ...+40 °C) Operaon without brake, self-venlated
Site altude
0 … 1000 m amsl
-
without current derang
1000 ... 2000 m. amsl Reduce rated output current by 5 %/1000 m
Air humidity
Without
condensaon
- Average relave humidity 85 %
Technical data
Standards and operang condions
Conformies and approvals
40