Technical data
General data and operating conditions
4
EDKMF2181 DE/EN/FR/ES/IT 3.0
43
H1_Daten-TabAbmess
4 Technical data
General data and operating conditions
Range Values
Order designation EMF2181IB
Communication media (system) CAN (DIN ISO 11898)
Lenze diagnostic interface
Communication media
(external)
Telephone analogue, 33.6 kbit/s, (V34)
Number of nodes at the CAN
bus
Max. 100
Baud rate
when communicating via CAN
– 20 kbit/s
– 50 kbit/s
– 125 kbit/s
– 250 kbit/s
– 500 kbit/s
– 1000 kbit/s
For communication via diagnostic interface
– 230.4 kbit/s
Voltage supply (external) via
separate power supply
18 … 30 V DC, max. 100 mA (in accordance with EN 61131-2)
Operating conditions Values Deviations from the standard
Climatic conditions
Storage 1 K3 to IEC/EN 60721-3-1 - 10 ... + 60 °C
Transport 2 K3 acc. to IEC/EN 60721-3-2 - 10 ... + 70 °C
Operation 3 K3 acc. to IEC/EN 60721-3-3 0 ... + 60 °C
Enclosure of attached module IP20
Degree of pollution 2 acc. to IEC/EN 61800-5-1