EasyManuals Logo
Home>Lenze>Servo Drives>MDFQA 132

Lenze MDFQA 132 User Manual

Lenze MDFQA 132
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Commissioning
Parameter setting
Servo controller ECS
6
42
BA33.0001 EN 2.0
6.2.2 Servo controller ECS
The input and output variables of the speed controller are normalised to the maximum
current I
max.
(C0022) and the maximum speed nmax. (C0011). This allows C0022 and
C0011 to directly influence the gain of the speed controller Vpn.
ƒ
The following applies to the servo controller ECS:
Vpn proportional n
max.
(C0011)
Vpn proportional 1/I
max.
(C0022)
6.2.3 Parameter setting of motor temperature detection
Stop!
ƒ
Integrated overload protection does not prevent overloading under all
conditions!
ƒ
Limit maximum current to required value!
The motor winding temperature is monitored by temperature sensors.
6.2.4 Parameterisation of the temperature sensor 9300 / ECS
ƒ
MCS06
–C1190=0(Standard,KTY83-110)
ƒ
MCS09/12/14/19
–C1190=1(Characteristic,KTY83-110+PTC150)
C1191/1 = 30
C1191/2 = 145
C1192/1 = 1180
C1192/2 = 2460
ƒ
MDXKX, MDFQA, MDXMA
–C1190=0