Commissioning
Function block interconnection servo inverter 9300
6
43
BA33.0001 E N 2.0
6.3 Function block interconnection servo inverter 9300
Stop!
Perform function block interconnection (servo inverter 9300) or I
2
xt
monitoring (servo inverter ECS) with dis connection after several seconds of
operation with I > I
N
, particularly in case of danger of blocking.
Example of function block interconnection for MCS06F41
I
O
= 1.5A, C0022 (I
max.
) = 5.3A
⇒
C0472/1 = 8.83%
OR1
≥
1
OUT
IN1
IN2
IN3
ARIT1
PT1-1
OUT
IN
CMP2
OUT
IN1
IN2
FCODE
C0472/1
MCTRL
DCTRL
TRIP-SET
CTRL
OUT
IN1
IN2
IACT
*
E1
E2
E3
E4
E5
C0114/1...5
DIGIN
1
2
3
4
5
28
X5
CINH
1
1
ST
FIXED0
Display:
z
Input value of PT1: C0642
z
Output value of PT1: C0689/1
z
Limit value: C0689/2
Calculation of limit value (FCODE 0472/1):
FCODE472
1
=
I
⋅
1
⋅
1.05
2
⋅
100
I
o
[A] Standstill current of motor
o
I
max
.
I
max
[A] Maximum current set in code C0022
Factor 1.05: for consideration of manufacturing tolerances and reaching the standstill
torque; disconnection at I>1.05*I
0
Time constant PT1: C0640 (currently 30 s)