Diagnostic aids 3-7
4512-420, -430
Registration
Margins
To set print registration:
1. Select REGISTRATION from the Diagnostics menu.
2. Select Margins from the REGISTRATION menu.
The Top margin sign/value pair blinks. This indicates it is the margin value being changed.
3. To select the margin value to be changed, press until the margin value pair you want to change is
blinking.
The print registration range is:
4. To change the margin value, press . When the value you want displays, press to save the value.
To verify the margin values are correct, you must print the Quick Test page. Press Go to print the test page.
While printing, Quick Test Printing displays. Once the Quick Test page completes printing, the
registration screen displays again.
5. To exit, press Return.
6. To Test the setting by printing the Quick Test page for all the sources, see “Quick Test” on page 3-14.
Select all the available sources.
Print the Quick Test Page on letter or A4 paper.
T=sxx* B=-sxx*
L=sxx*
Variable Description Value
s sign blank for positive values, “-” for
negative values
B= Bottom margin -20 to +20—Each increment causes
approximately 0.55 mm shift in the
bottom margin.
T= Top margin -16 to +16
L= Left margin -25 to +25