Page #27 background imageLoading...
Page #27 background image
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
(When discharging, contact the metal plug of Power cord with earth line.)
Degree of Resistance is not in 300°æ30
Turn the Dryer’s Power Off, then measure resistance.
When measuring resistance
Is resistance 300
±
20 ?
YES
NO
Check Semi-
conductor and
Harness Connector
Check Harness
linking connector
Take 6pin Connector from
the Controller.
Test 8
Motor Assembly, DC, Pump
27