50
DATE
22.12.2003
COMPILER TECO/ATI
REG. CODE
1-5302-467
MODEL N°
50707
DATE OF ISSUE
06-95
REVISION 05
ENDORSED
94
95
IX
LUBRICATION SYSTEM
Oil pressure curve at idle speed
The curve is obtained at the oil filter port with engine running at a
constant speed of 1200 r.p.m. in no-load conditions; pressure is
given in bar and temperature in centigrades.
The curve represents the minimum pressure value while the
maximum value is 5 bar.
Oil pressure curve at full speed
The curve is obtained at the oil filter port with engine running at 3000
r.p.m. at the N power; pressure is given in bar and temperature in
centigrades.
The curve represents the minimum pressure value while the
maximum value is 5 bar.
Note: After the running-in period the lube max. temperature should
be less than the room temperature +95°C.