Page #133 background imageLoading...
Page #133 background image
–129–
1. Compare the results of step 3 with step 2. Ice
production is normal when these numbers match
closely. If they match closely, determine if:
Another ice machine is required.
More storage capacity is required.
Relocating the existing equipment to lower the load
conditions is required.
Contact the local Manitowoc Distributor for information
on available options and accessories.
Installation/Visual Inspection Checklist
Possible Problem List
Corrective Action List
Ice machine is not level
Level the ice machine
Condenser is dirty
Clean the condenser
Water filtration is plugged (if used)
Install a new water filter
Water drains are not run separately and/or are not
vented
Run and vent drains according to the Installation
Manual
Line set is improperly installed
Reinstall according to the Installation Manual