–16–
Factory Equipment Refrigerant Amounts
ICE MACHINE HEAD SECTION
Q0600C/Q0800C/Q1000C/SU1000C/Q1400C
Each ice machine head section ships from the factory
with an R-404A refrigerant charge appropriate for the
entire system operation. The serial tag on the ice
machine indicates the refrigerant charge. The
refrigerant charge is sufficient to operate the ice
machine in ambient temperatures between -20°F
(-28.9°C) and 130°F (54.4°C), (CVD1476, 50°F to
110°F, 10°C to 43°C) with line set lengths of up to
100 ft. (30.5 m).
QDUAL
Each QDUAL ice machine head section ships from the
factory with an R-404A refrigerant charge appropriate
for installations with up to 50" of refrigerant tubing. The
serial tag on the ice machine indicates the refrigerant
charge. For line set runs longer than 50 ft., 1 lb. of
additional refrigerant must be added for each 10 ft. of
line set run. The receiver is designed to hold a charge
sufficient to operate the ice machine in ambient
temperatures between -20°F (-28.9°C) and 120°F
(49°C), with line set lengths of up to 100 feet (15 m)
The 60-month compressor warranty (including the
36-month labor replacement warranty) will not apply
if the Manitowoc Ice Machine and Manitowoc CVD
®
Condensing Unit are not installed according to
specifications. This warranty also will not apply if the
refrigeration system is modified with a condenser,
heat reclaim device, or other parts or assemblies not
manufactured by Manitowoc Ice, Inc.