–181–
Q1400C/CVD1475 SERIES REMOTE AIR COOLED
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0 70/21.1 90/32.2
-20 to 70/
-29 to 21.1
11.1-12.6 12.6-14.4 14.4-16.4
.75-2.5
90/32.2 11.3-12.9 12.9-14.7 14.8-16.8
100/37.8 12.2-13.9 14.1-16.0 16.1-18.3
110/43.3 13.5-15.4 15.8-17.9 16.3-18.5
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0 70/21.1 90/32.2
-20 to 70/
-29 to 21.1
1375 1225 1085
90/32.2 1350 1200 1060
100/37.8 1260 1110 980
110/43.3 1150 1000 970
1
Based on average ice weight of one Harvest cycle
12.00-13.50 lb. (6.00-6.75 lb. per evaporator).
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10.0
260-215 42-22 140-185 70-95
70/21.1 275-220 42-24 150-190 70-95
80/26.7 285-225 43-25 155-195 85-95
90/32.2 290-235 44-26 160-195 85-100
100/37.8 335-260 46-28 170-200 85-115
110/43.3 385-310 50-30 180-210 95-125
Refer to page 176.