–200–
REFRIGERANT REUSE POLICY
Manitowoc recognizes and supports the need for proper
handling, reuse, and disposal of CFC and HCFC refrigerants.
Manitowoc service procedures require recapturing
refrigerants, not venting them to the atmosphere.
It is not necessary, in or out of warranty, to reduce or
compromise the quality and reliability of your customers'
products to achieve this.
Manitowoc approves the use of:
1. New Refrigerant
Must be of original nameplate type.
2. Reclaimed Refrigerant
Must be of original nameplate type.
Must meet ARI Standard 700 (latest edition)
specifications.
3. Recovered or Recycled Refrigerant
Must be recovered or recycled in accordance with
current local, state and federal laws.
Must be recovered from and reused in the same
Manitowoc product. Reuse of recovered or recycled
refrigerant from other products is not approved.
Recycling equipment must be certified to ARI Standard
740 (latest edition) and be maintained to consistently
meet this standard.
Recovered refrigerant must come from a “contaminant-
free” system. To decide whether the system is
contaminant-free, consider:
Type(s) of previous failure(s)
Whether the system was cleaned, evacuated and
recharged properly following failure(s)
Whether the system has been contaminated by this
failure
Compressor motor burnouts and improper past service
prevent refrigerant reuse.
Refer to “System Contamination Cleanup” to test for
contamination.
4. “Substitute” or “Alternative” Refrigerant
Must use only Manitowoc-approved alternative
refrigerants.
Must follow Manitowoc-published conversion
procedures.
Important
Manitowoc Ice, Inc. assumes no responsibility for use of
contaminated refrigerant. Damage resulting from the use of
contaminated, recovered, or recycled refrigerant is the sole
responsibility of the servicing company.