Maintenance work on the carrier
7.11 Vehicle brake
09.03.2018
Maintenance manual 3 302 744 en 7 - 81
GMK5250L
7.11 Vehicle brake
7.11.1 Checking the wear display
On the brake calliper
Each brake calliper (1) carries two brake pads
(2), arranged one to the left and one to the
right of the brake disc (3).
The lining thickness (A) is monitored by an
electric wear indicator on the brake calliper (1).
If the lining thickness (A) falls below the per-
missible minimum value, a warning message
is displayed on the on-board computer in the
driver's cab.
On the on-board computer
• Familiarise yourself with the correct
operation of the on-board computer;
à Operating manual.
The Operation and Maintenance menu also
provides information on the condition of the
disc brakes.
• Check the outstanding warning messages
every day.
s