Maintenance work on the carrier
7.15 Hydraulic system
09.03.2018
Maintenance manual 3 302 744 en 7 - 105
GMK5250L
7.15.5 Changing the ventilation filter
Reducing the
interval
• Under difficult operating conditions – at extremely sandy or dusty loca-
tions – you must change the ventilation filters earlier than normal.
Spare parts and
tools
Prerequisites – The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
• Remove the cover (1).
• Change the filter (2) and fasten the cover.
M 12
Designation Quantity GROVE part no.
Filter 1 03324588
O
Risk of damage to the environment from filter residues.
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.