Maintenance work on the carrier
7.15 Hydraulic system
09.03.2018
Maintenance manual 3 302 744 en 7 - 101
GMK5250L
7.15 Hydraulic system
7.15.1 Checking the oil level
Prerequisites – The truck crane must be aligned horizontally at on-road level;
à Operating manual.
– The outriggers must be retracted; à Operating manual.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
• Check that oil is visible in the middle of the
inspection glass (1) before starting work.
If the oil level is too low
• Top up the oil; à p. 7 - 113.
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable receptacles. Wipe up any con-
sumables that have leaked.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.
D
S
Risk of damage to the hydraulic system.
When working with hydraulic oil, cleanliness is imperative.
Even fresh hydraulic oil should be filtered.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals