Maintenance work on the superstructure
8.6 Hydraulic system
09.03.2018
Maintenance manual 3 302 744 en 8 - 45
GMK5250L
Draining oil
• Place a receptacle underneath the valve.
• Screw the connecting piece and hose onto
the valve (1) and drain the oil;
à Handling
the valves
, p. 7 - 112.
• Change the filters; à p. 8 - 39.
Topping up the oil
• Remove the cap (1) and the filter (2).
• Add new oil via the filler neck (3) through a
filter until the level reaches the centre of the
inspection glass (4).
• Tighten the cap and filter.
s
O
Risk of environmental damage due to leaking consumables.
Use the supplied connecting piece and hose and a receptacle with sufficient
capacity to drain the hydraulic oil.
S
Risk of damage to the hydraulic system.
Cleanliness is of the utmost importance when handling hydraulic oil.
Even fresh hydraulic oil must be filtered before it is added to the tank.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals