OPERATING CONTROLS AND PROCEDURES RT770E OPERATOR MANUAL
3-20 Published 04-04-2017, Control # 446-09
MISCELLANEOUS CONTROLS AND
INDICATORS
Fuse Panel
The fuse panel (1) (Figure 3-13) is located behind the cab
seat and on the cab fuse and relay panel assembly. It
contains up to 20 fuses that protect the various electrical
components of the crane.
Buzzer
The buzzer (2), located behind the cab seat, sounds when
the following conditions exist:
the ignition switch is turned to RUN; buzzer will sound
for two seconds
after the engine is started until the proper hydraulic oil
pressure is reached
engine stop
emergency stop switch activated
transmission service
low brake pressure
high hydraulic oil temperature
high transmission oil temperature
low steer pressure condition (for CE units)
hoist third wrap condition (for CE units)
Rated Capacity Limiter (RCL) Emergency
Override Switch (Non-CE Certified Cranes)
The RCL system, when programmed accurately, will lockout
the three craning functions—boom down, telescope extend,
and hoist up—when a lift is attempted at or above the crane's
capacity or when a two-block condition exists. Locking out
these three functions prevents the overload or two-block
condition from worsening.
The RCL emergency override switch (3, Figure 3-13) is a key
operated switch that is located inside the operator cab on the
panel assembly behind the seat. When actuated (turned
clockwise), the switch will override and prevent the RCL from
locking out the three craning functions (boom down,
telescope extend, and hoist up) should an overload or two-
block condition occur.
Overriding the RCL with this switch should only be done in
the case of an emergency or when servicing the boom.
A flashing light on the RCL display indicates the switch has
been activated.
Refer to the RCL operator's manual for more information.
Rated Capacity Limiter (RCL) Emergency
Override Switch and Indicator (CE Certified
Cranes)
The RCL system, when programmed accurately, will lockout
the three craning functions—boom down, telescope extend,
and hoist up—when a lift is attempted at or above the crane's
capacity or when a two-block condition exists. Locking out
these three functions prevents the overload or two-block
condition from worsening.
The RCL emergency override switch is located inside a key-
locked single-door enclosure (1, Figure 3-14) that is
attached to the outside rear of the operator's cab. The switch
is a two-position momentary rocker switch with integral
WARNING
Loss of RCL Monitoring Hazard!
The RCL Emergency Override switch is to be used in
emergency situations only.
Do not operate the crane with the RCL overridden during
normal operations.
When the RCL is overridden always have a helper on the
ground to signal you.
WARNING
Loss of RCL Monitoring Hazard!
The RCL Emergency Override Switch is to be used in
emergency situations only.
Do not operate the crane with the RCL overridden during
normal operations.
When the RCL is overridden, always have a helper on the
ground to signal you.
FIGURE 3-13
7649-9
2
1
3

Table of Contents

Other manuals for Manitowoc Grove RT770E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT770E and is the answer not in the manual?

Manitowoc Grove RT770E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT770E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals