Part Number Preliminary 6/11 327
I0870C
Remote Air-Cooled Condensing Unit Model
Characteristics vary depending on operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
11.0-12.6 12.1-13.8 13.4-15.4
.75-2.5
90/32 12.5-14.4 12.8-14.6 14.9-17.0
100/38 13.6-15.5 14.7-16.9 1539-18.2
110/43 14.9-16.9 15.8-18.0 16.9-19.3
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
665 610 555
90/32 590 580 505
100/38 550 510 475
110/43 510 480 450
1
Based on average ice slab weight of 5.75-6.50 lb.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
200-250 50-30 170-200 65-75
70/21 250-290 60-30 180-210 75-95
80/27 260-300 60-31 190-220 75-95
90/32 270-310 60-33 200-230 80-100
100/38 300-380 80-34 210-250 90-110
110/43 310-390 80-35 220-260 105-130