Part Number 80-1505-3 6/11 103
Step 16 The ice machine will stop after the sanitize
cycle (approximately *35 minutes). Place the toggle
switch in the OFF position and disconnect power to
the ice machine.
*S3070C Only - 80 minutes.
Step 17 Refer to step 6 and disassemble
components. After dissembling proceed to step 18.
Step 18 Mix a solution of sanitizer and warm water.
Step 19 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or
sponge to liberally apply the solution to all surfaces of
the removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.
Step 20 Use 1/2 of the sanitizer/water solution to
sanitize all food zone surfaces of the ice machine and
bin (or dispenser). Use a cloth or sponge to liberally
apply the solution. When sanitizing, pay particular
attention to the following areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom and
sides
Bin or dispenser
Do not rinse the sanitized areas.
Step 21 Install the removed parts, restore power and
place the toggle switch in the ICE position.
!
Warning
Disconnect the electric power to the ice machine
at the electric service switch box.
Solution
Type
Water Mixed With
Sanitizer 6 gal. (23 l) 4 oz (120 ml) sanitizer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SD1072C and is the answer not in the manual?

Manitowoc QuietQube SD1072C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SD1072C
CategoryIce Maker
LanguageEnglish

Related product manuals