122 Part Number 80-1505-3 6/11
Safety Timers
The control board has the following non-adjustable safety
timers:
The ice machine is locked into the freeze cycle for 6
minutes before a harvest cycle can be initiated.
The maximum freeze time is 60 minutes at which time
the control board automatically initiates a harvest
sequence (steps 5 & 6).
The maximum harvest time is 3.5 minutes at which time
the control board automatically ends the harvest cycle.
When the bin switch is closed a freeze sequence initiates
(steps 3 & 4). When the bin switch is open an automatic
shutoff sequence initiates.
The maximum water fill is 6 minutes.
Water Assist Harvest Feature
Twin & Quad Evaporators Only:
Typical duration of a Harvest sequence is less than 2.5
minutes. When the Harvest sequence time reaches 4
minutes, the following occurs:
4 minutes into a Harvest sequence: The water fill valve will
energize to fill the trough with water.
5 minutes into a Harvest sequence: The water pump will
energize and flow water over the evaporators.
The water fill valve and water pump remain on until all bin
switches have been activated, or until the 7-minute Harvest
sequence time limit is reached.
Warm Water Rinse Cycle
Single & Twin Evaporators Only:
Closing the back of the evaporator allows ice to build up on
the rear of the evaporator and the plastic evaporator frame
parts. After 200 freeze/harvest cycles have been complete
the control board will initiate a warm water rinse.
After the 200th harvest cycle ends:
The Clean and Harvest LED’s energize to indicate the ice
machine is in a warm water rinse.
The compressor and harvest valve remain energized.
The water pump energizes.
The water inlet valve energizes until water contacts the
water level probe.
The compressor and harvest valve warm the water for 5
minutes, then de-energize.
The water pump remains energized for an additional 5
minutes (10 minute total on time) then de-energizes.
The warm water rinse cycle can be terminated by moving the
toggle switch to the OFF position, then back to ICE.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SD1072C and is the answer not in the manual?

Manitowoc QuietQube SD1072C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SD1072C
CategoryIce Maker
LanguageEnglish

Related product manuals