262 Part Number 80-1505-3 6/11
S1470C/CVD1486 REMOTE WATER COOLED
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
CONDENSER WATER CONSUMPTION
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
35 to 70/
2 to 21
11.3-13.4 12.5-14.8 13.9-16.5
.75-2.5
80/27 11.3-13.4 12.5-14.8 14.0-16.6
90/32 11.3-13.4 12.5-14.9 14.1-16.7
100/38 11.3-13.4 12.5-14.9 14.1-16.7
1
Times in minutes.
Air Temp.
Around the
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
35 to 70/
2 to 21
1350 1235 1120
80/27 1350 1235 1115
90/32 1350 1230 1110
100/38 1350 1230 1110
1
Based on average ice weight of one Harvest cycle 12.0-14.0 lb.
(6.0-7.0 lb. per evaporator).
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
35 to 70/
2 to 21
235-250 60-36 200-225 70-95
80/27 235-255 60-38 200-225 75-95
90/32 240-260 60-38 205-230 80-95
100/38 245-265 65-40 205-230 80-95
110/43 245-265 70-40 210-235 80-100
Condenser
Water
Consumption
90/32 Air Temperature Around Ice Machine
Water Temp. °F/°C
50/10 70/21 90/32
Gal/24 Hours 950 1700 6000